This simulates the condenser. CAR removes condenser air, but only to a point, steam ejectors use the venturi effect to remove air, steam is used to run the sjaes, and they also eject some steam but its condensed by the HX supplied by the CCS (Component Cooling System), the condensate is pumped into the Howell. Steam going into the condenser Carry's non condens-able gasses like oxygen and make cond circ less effective in condensing water. therefore less steam being condensed means more pressure. ------------------------------------------------------- you can use fw pump to control rpv water level. but it pumps water out of the deaerator, so that makes it drop. to control deaerator level you simply raise the condensate pump over the setpoint of fw pump, and vice versa. Condensate pump; pumps water from hotwell. Hotwell water level can be controlled by the steam coming in vs the condensate outflow.
Physics is still being worked on. So expect bugs. Not 100% realistic but this is for my upcoming realistic bwr simulation. Panel GUI is a WIP.